Voltage and Ohm's calibration
How to set the voltage and Ohms calibration after replacing parts
Do not change the voltage calibration unless you have replaced the main board or Kaffelogic support has instructed you to do so.
Do not change the Ohms calibration unless you have replaced the main board, element or Kaffelogic support has instructed you to do so.
Setting voltage calibration
Plug you roaster in to a power meter or use a multimeter to read the supply voltage of the plug.
Hold down both the + and - buttons while you turn the roaster on. It will enter calibration mode.
Press ≡ until you see ‘Press ⏵now for supply voltage’. Press ⏵
Use the + and - buttons and set the roaster to the same value as your power meter. If you can not measure you supply voltage set it to the best know supply voltage.
Press ⏵ twice to save the setting. The display will briefly show ‘Saved'.
Turn the roaster off to exit calibration mode.
Setting Ohm’s calibration
Hold down both the + and - buttons while you turn the roaster on. It will enter calibration mode.
Press ≡ until you see ‘Press ⏵now for element Ohms’ Press ⏵
Use the + and - buttons and set the ohms to the value supplied, value measured or the appropriate value.
220-240V set at 34.4 ohms
110-120V set at 10.2 ohms
100V set at 7.2 ohms
Press ⏵ twice to save the setting. The display will briefly show ‘Saved'.
Turn the roaster off to exit calibration mode.
Filter by label
There are no items with the selected labels at this time.